中文  /  EN

ABOUT SHENTONG

Fugitive Test

  • Categories:试验检测
  • Time of issue:2020-05-15 00:00:00
  • Views:0
Description:
Description:
Information

In order to cope with the regulations on VOC (volatile organic compound) emissions of global chemical process control equipment, API has enacted emission standards on valve fugitive for linear motion valves and 1/4 rotary valves, which are API 624 and API 641 (not officially released). Meanwhile, to control the fugitive of linear motion valves, API has enforced API 624 fugitive requirements on the valves certified by API STD 600 label, meaning that all certified valves must pass the API 624 test. We have built a test bench according to API 624 standards, which can test as large as 20-inch valves. The API 624 can be completed under the witness of a third party.

API 624 fugitive test parameters

Test object: gate valve/stop valve;

Test pressure: 600 psig (4.14MPa);

Test temperature: RT, 260℃ (stuffing box temperature);

Temperature cycle: RT~260℃ cycle 3 times;

Mechanical cycle: 310 opening and closing times;

Test medium: ≥97% methane;

Test method: probe method;

Allowable leakage: ≤100ppmV;

 

API 624 fugitive test

 

江苏神通

Fugitive test personnel are assembling the valve to be tested

 

江苏神通

API 624 test device

 

江苏神通

System interface of API 624 fugitive test

Scan the QR code to read on your phone

Stock information

News

Support hotline:

Metallurgical Marketing Office: 86-513-83335938

Office of Nuclear Power: 86-513-83620011

Energy Marketing Department: 86-513-83330958

底部版权

Time of issue:2020-04-24 00:00:00
Copyright © 2020 Jiangsu Shentong Valve Co., Ltd.  - All rights reserved  苏ICP备05041592号   |   Powered by www.300.cn